Skip to Content
ID
7-508-1101
Name
Water Pump, Drinking Water Supply – Untreated Source
Status
Published
Version
1.5
Updated
11/5/2019 9:19:25 AM
Original Release
05/26/2005
Last Major Release
11/05/2019
Description
The Water Pump, Drinking Water Supply – Untreated Source is equipment that pumps untreated water to a water treatment plant
Resource Category
Public Works
Primary Core Capability
Infrastructure Systems
Secondary Core Capability
 
Resource Kind
Equipment
Overall Function
The Water Pump, Drinking Water Supply – Untreated Source is equipment that servers as a temporary pump to supply the water treatment plant with source water for processing
Composition and Ordering Specifications
1. Requestor specifies desired/comparable pump manufacturer and model, as necessary 2. Requestor specifies gallons per minute (GPM) capacity, maximum solids handling capacity, necessary equipment head, and equipment suction 3. Requestor specifies any additional materials or equipment necessary to meet deployment requirements 4. Requestor specifies the size and suction of discharge connections 5. Provider establishes whether pumps are trailer-mounted or skid-mounted 6. Can be ordered with staff using the National Incident Management System (NIMS) Utility Worker Specialist – Water Sector Infrastructure
Supporting Core Capabilities
None
Components
Component Notes  
Equipment DescriptionEquipment weight varies between manufacturers. Requestor specifies any weight restrictions.
Component Types
Type Attribute
Type 1Same as Type 2, PLUS: Portable, skid-mounted or trailer-mounted (6,500 lbs.)
Type 2Same as Type 3, PLUS: Portable, skid-mounted or trailer-mounted (4,959 lbs.)
Type 3Same as Type 4, PLUS: Portable, skid-mounted or trailer-mounted (3,200 lbs.)
Type 4Same as Type 5, PLUS: 1. Solids handling to 3 inches 2. Portable, skid-mounted or trailer-mounted (1,734 lbs.)
Type 51. Self priming 2. Solids handling to 2 inches 3. Self-contained diesel power supply 4. Automatic start/stop 5. Portable, skid-mounted or trailer-mounted (1,586 lbs.)
EQUIPMENT PUMP CAPACITY (GALLONS PER MINUTE)Not Specified
Component Types
Type Attribute
Type 13,500
Type 2Same as Type 3
Type 32,000
Type 4700
Type 5300
EQUIPMENT HEAD (FEET)Not Specified
Component Types
Type Attribute
Type 150
Type 2Same as Type 3
Type 335
Type 420
Type 540
Equipment Suction Side (inches)Not Specified
Component Types
Type Attribute
Type 110
Type 28
Type 36
Type 44
Type 53
737
Notes
References
Reference
FEMA, NIMS 509: Utility Worker Specialist – Water Sector Infrastructure
FEMA, National Incident Management System (NIMS), October 2017
FEMA, National Response Framework, June 2016